Installation

Ventilation

During installation, ensure there is
sufficient ventilation at the rear of the
appliance so that steam and warm air
are able to escape without hindrance.
The ventilation area in the furniture
unit and the space underneath the
ceiling must amount to at least
200 cm².
Otherwise condensate may form and
the appliance or the furniture unit may
be damaged.
Installation
Before installation, make sure that
there is no power supply to the
machine. This also applies should it
ever need to be taken out of its
housing unit.
The machine may only be operated
when built-in and in an ambient
temperature range between +10 °C
to +38 °C.
You will need two Allen keys (size 3
and 5) for installing the machine.
80
To ensure the appliance door is flush
with the furniture front, a seal around
the building-in niche is needed or a
sealing strip must be adhered to the
appliance.
^ If there is not a seal around the
building-in niche, adhere the Miele
sealing strips from the back (see
picture) before installing the coffee
machine.
The sealing strips can be purchased
from Miele.