HP 7470A Interfacing And Programming Manual page 203

Graphics plotter
Hide thumbs Also See for 7470A:
Table of Contents

Advertisement

OO
OP
OS
OW
The Output Options Instruction
Page7-7
00
(;)
Purpose:
Used to output features implemented on the plotter.
Response: 0,1,0,0,1,0,0,0[TERM]
Indicates arcs and circle instructions are included (available
only with RS-232-C plotters that have the Serial Prefix
number 2308A or higher).
Indicates pen select capability is included (available on all plotters).
The Output P1 and P2 Instruction
Page2-5
OP (;)
Purpose:
Used to output the plotter unit coordinates of the scaling
points P1 and P2.
Response:
Plx, Ply, P2X,P2y [TERM] — four integers in ASCII.
Range —dependent on settings of paper switch.
US
0 < X-coordinate S 10 300
0 S Y-coordinate < 7650
A4
0 < X—coordinate < 10 900
0 < Y—c0ordinate< 7650
The Output Status Instruction
Page7-8
08 (;)
Purpose:
Used to output the p1otter'sstatus.
Response:
status [TERM] —integer in ASCII in the range 0 to 255.
Power—onstatus, 24.
The Output Window Instruction
Page2-10
OW (;)
Purpose:
Used to output the"plotter unit coordinates of the lower­
left and upper—rightcorners of the current window.
Response:
Xlower left, Ylower left, Xupper right, Yupper right [TERM] —
integers in ASCII. Range same as OP.
INSTRUCTION SYNTAX B-7

Advertisement

Table of Contents
loading

Table of Contents