Checking the Calibration
EN
Check that the sensors were calibrated correctly.
It is necessary to check the calibration of the sensors on both the left and right sides. The right-side pedaling monitor sensor is
used as an example in this description. The procedure to check the left side is the same as for the right side.
1
Position the crank arm so it is perpendicular to the ground, pointing downward.
2
In the sensor screen of the SGX-CA500, tap [Pedaling Monitor R] and then [Force Preview] in order.
3
Confirm that the values that appear on the SGX-CA500 Force Preview are within the range shown below.
•
Tangential Direction Force: 0 ± 3 N
•
Radial Direction Force: 0 ± 3 N
Checking the calibration of the right side is finished. Check the calibration of the left side in the same way.
After finishing the calibration, pedal a bicycle to confirm that the pedaling vector display appears. If the vector is not displayed,
perform the calibration again.
24