Toshiba Strata CTX Programming Manual page 73

Digital business telephone systems
Hide thumbs Also See for Strata CTX:
Table of Contents

Advertisement

F
IELD
08 E911 Service
09 DR Override by SSD
10 Auto Station Release
11 ISDN SPID
12 Night Mode Relay
13 BGM External Paging
14 Lost Call Destination
15 COS Override Code
16 Multi-Conference
17 Caller Number Display
18 Night Bell Relay
19 Display Preference
Strata CTX Programming - Part 2: CTX WinAdmin Programming 04/03
D
ESCRIPTION
Enable E911 Service availability.
Possible values: Enable (default) or Disable
Enable DR Override by System Speed Dial.
Possible values: Enable (default) or Disable
Enable Automatic Station Release.
Possible values: Enable (default) or Disable
Enable Auto Service Profile Identifier (SPID).
Possible values: Operable or Not Operable (default)
Assign BIOU Relay as the Night Relay. This relay activates when the system is
in the Night Mode.
Possible values: 0~8 (default = 0)
BIUO1 provides relays 1 to 4; BIUO2 provides relays 5 to 8
Note
On CTX100 the ACTU built-in relay is programmed as relay 5. For this
operation, in Program 100 the BIOU2 must be installed in Cabinet 2,
Slot 5, PCB code 20.
Set the External Page Group Number that includes the external paging zones
to which BGM will be sent. See Program 503
Possible values: 0~4 (CTX100)
0~8 (CTX670 Basic)
0~16 (CTX670 Expanded) (default = 0)
Enter Lost Call Destination. If no value is entered in this field any previously
programmed data is lost.
Possible values: Up to 5 digits (default = no value)
Select Class of Service Override Code.
Possible values: 1~8 (default = 1)
Enable Multi-Conference capabilities for Analog Internal Calls and Outgoing
Calls.
Possible values: Enable or Disable (default)
Enable Caller Number Display. If a soft key display competes with a Caller ID,
the Caller ID displays.
Possible values: Enable (default) or Disable
Assign BIOU Relay as the Night Bell Relay; this relay activates whenever Night
Ringing takes place.
Possible values: 0~8 (default = 0)
BIUO1 provides relays 1 to 4; BIUO2 provides relays 5 to 8
Note
On CTX100 the ACTU built-in relay is programmed as relay 5. For this
operation, in Program 100 the BIOU2 must be installed in Cabinet 2
Slot 5, PCB code 20.
Select Display Preference.
Possible values: DNIS (default) or Caller ID
System
105 System Data
4-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata ctx100Strata ctx670

Table of Contents