Table 1-6
ECS incoming port connections
Port Range
Protocol
1024-5000
H.245 (TCP) H.245 routed
(configure
within that
range in the
Windows
registry)
1719
RAS (UDP)
1720
Q.931 (TCP) Q.931 routed
3271
ECS XML
RADVISION | RADVISION Port Security Reference Guide
Functionality
Direction Result of
Both
calls
RAS
Both
Both
calls
Incoming XML
Both
connection
Description
Blocking Port
on Firewall
No H.245
Any H.323 entity H.245 port
(except in
The number of ports ECS needs for this
Q.931 routed
purpose is the maximum calls allowed by
and direct
your license multiplied by four.
mode)
To limit ECS's use of ports within the range
of 1024-5000:
1.
Close ECS.
2.
Open the registry.
3.
Navigate to HKEY_LOCAL_MACHINE\
SOFTWARE\RADVISION\
Enhanced Communication Server\
Storage\Config\Stack
4.
Create a new key of type REG_SZ called
PortMin. Give it the value of the
minimum port number ECS should use.
5.
Create a new key of type REG_SZ called
PortMax. Give it the value of the
highest port number ECS should use.
6.
Restart ECS.
There may be other applications on the
same computer which altered the global
maximum port for all processes running on
that Windows PC. Verify this global
maximum is unchanged in the
HKEY_LOCAL_MACHINE\
SYSTEM\CurrentControlSet\Services\
Tcpip\Parameters\MaxUserPort registry
key. If this key is not defined, its default
value is 5000.
No RAS
Any H.323 entity using RAS signaling
capabilities
No signaling
Any H.323 entity using Q.931 signaling
capabilities
(except in
direct mode)
No incoming
XML server
XML
connection