Setting The Clamp Position - Pioneer PDP-502MX Manual

Plasma display monitor
Hide thumbs Also See for PDP-502MX:
Table of Contents

Advertisement

7) Setting the clamp position

Plugging in RGB (G ON SYNC) signals and a sync signal simultaneously may produce inappropriate intensity
reproduction, with an over-bright screen or images with a greenish cast. If this occurs, set "CLAMP : MODE 2". For
most situations, leave "CLAMP : MODE 1".
Clamp pulse (a timing pulse necessary for intensity reproduction), is generated in two ways, "a" and "b", as shown
in Figure 1.
Figure 1: Generation of a clamp pulse
a. Generating a clamp pulse
from separate sync
Clamp effective area
G (Green)
H (Separate
Sync Signal)
Clamp pulse
b. Generating a clamp pulse
from G ON SYNC
Clamp effective area
G (G ON SYNC)
Clamp pulse
Sync signals are monitored in "CLAMP : MODE 1", and the unit is automatically switched to generate a clamp pulse by
method "a" shown in Figure 1 in the presence of sync signal, and by method "b" in the absence of a sync signal. But
when a sync signal is fed simultaneously with G ON SYNC, the unit perceives a sync signal, and generates a clamp
pulse as shown in "a" in Figure 1. The generated clamp pulse is mis-timed, making correct reproduction of intensity
impossible.
In this case, unplug the sync signal or set "CLAMP : MODE 2".
In "CLAMP MODE 2", the clamp pulse is generated by pulse"b"in Figure 1, whether or not a sync signal is present,
ensuring correct reproduction of intensity.
(NOTE) The figures above are for illustrative purposes only.
(NOTE) Please regard the case of composite sync input as being the same as the case of separate sync input.
Set-able condition:
RGB signal received via INPUT 3 or 4.
Factory preset:
1 Select SETUP.
Screen 1
MAIN MENU
PICTURE
SCREEN
ALL RESET
POWER SAVE
3SET UP
MENU : MENU OFF
5∞
3
: SELECT
(NOTE) No setting possible during input of component image signals
INPUT 3 : MODE 1
INPUT 4 : MODE 1
CONTRAST : 0
: 0
BRIGHT
: 0
COLOR
: 0
TINT
: 0
SHARP
RESET
SET : NEXT
Figure 2: When a sync signal is supplied simultaneously
with G ON SYNC
Clamp effective area
G (G ON SYNC)
H (Separate
sync signal)
Clamp pulse (In
CLAMP:MODE 1)
Clamp pulse (In
CLAMP:MODE 2)
2 Move the cursor to CLAMP, and use the SET
button to change the setting.
Pressing the SET button toggles clamp mode
between MODE 1 and MODE 2.
Screen 2
SET UP
TERMINAL
: D-SUB
SETTING
: PC
SIGNAL
: RGB
3CLAMP
: MODE 1
ABL
: OFF
H. ENHANCE :
V. ENHANCE :
EXIT
5∞
3
: SELECT
SET : CHANGE
Menu Mode
Correct clamp timing
0
0
103

Advertisement

Table of Contents
loading

Table of Contents