Asus DS300i User Manual page 392

User manual
Hide thumbs Also See for DS300i:
Table of Contents

Advertisement

Reported Event
Disk array has been
removed
Disk array settings have
been changed
Drive Interface Controller
Drive-interface controller
found
Drive-interface controller
is NOT found
Drive-interface
diagnostics has passed
Drive-interface
diagnostics has failed
Drive-interface controller
has generated a general/
data parity error.
Enclosure
Enclosure temperature is
above the threshold/
warning threshold
Enclosure temperature is
above the critical
threshold
Enclosure temperature is
within the normal range
Event Log
Event logging is enabled
Event logging is disabled Event logging has been disabled.
Event log buffer is cleared
in RAM
The physical drives of the disk array were removed
from the enclosure.
The user successfully disk array settings. See
page 156 (ASUS Storage Management) or page 230
(CLU).
Normal.
Restart the ASUS Storage. See page 130 (ASUS
Storage Management) or page 280 (CLU). If this
message appears repeatedly, contact Technical
Support. See page 402.
Normal.
Restart the ASUS Storage. See page 130 (ASUS
Storage Management) or page 280 (CLU). If this
message appears repeatedly, contact Technical
Support. See page 402
Drive-to-controller parity error. If this message
appears repeatedly, contact Technical Support. See
page 402.
The ASUS Storage is overheating. Check for airflow
around and through the ASUS Storage, and verify
that all fans are working. Replace fans as needed.
The ASUS Storage is seriously overheating. Check
for airflow around and through the ASUS Storage,
and verify that all fans are working. Replace fans as
needed.
Normal.
Event logging has been successfully enabled.
The event log was cleared.
373
Chapter 10: Troubleshooting
Corrective Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds300f

Table of Contents