may be bad, and may need replacement. If you have
additional CPU boards available for this system, replace
one CPU board at a time and see if the error goes away.
Call your HP service representative for further assistance
2B2h Incorrect Drive A type -- run SETUP
This error will be displayed if floppy diskette drive A does not fit
the drive type specified in the Setup menu.
Actions You Can Take
Enter the SETUP menu by pressing the F2 key during
1.
POST.
Select the correct floppy diskette type. Save the new
2.
configuration, and exit SETUP. The system reboots, and
this error should go away.
If the error persists, replace the floppy drive.
3.
2B3h Incorrect Drive B type -- run SETUP
This error will be displayed if the floppy diskette drive installed in
the system does not fit the drive type specified in the Setup
menu.
Actions You Can Take
Enter the SETUP menu by pressing the F2 key during
1.
POST.
Select the correct floppy diskette type. Save the new
2.
configuration, and exit SETUP. The system reboots, and
this error should go away.
If the error persists, replace the floppy drive.
3.
2F0 CPU ID:xx
This error will occur if there is a CPU failure in the system. The
number in the error message indicates the processor that failed.
Actions You Can Take
Reboot the system to check if this error is a soft error. If
1.
the error is a soft error, it will go away.
If the error does not go away, replace the indicated
2.
processor. Reboot again and see if the error goes away.
Call your HP service representative for further assistance.
2F4 EISA CMOS not writable
This error will occur if the CMOS writes fail. If the error persists,
replace the system board. Call your HP service representative for