Download Print this page

HP D7171A - NetServer - LPr Manual page 5

Hp netserver lxr pro8 post and beep codes
Hide thumbs Also See for D7171A - NetServer - LPr:

Advertisement

through POST, when the BIOS was updating the CMOS and
NVRAM data in the system.
Actions You Can Take
Enter the SETUP menu by pressing the F2 key during the POST,
and fix the system configuration.
281 Memory size found by POST different from EISA CMOS
This error will occur if new memory is added to the system.
Actions You Can Take
Enter the SETUP menuby pressing the F2 key during the POST,
and fix the system configuration.
2B0h Floppy drive A error
This error will be displayed if the floppy drive A failed the POST
test.
Actions You Can Take
Check if power is connected to the floppy drive.
1.
Check if the floppy drive's cables are connected correctly.
2.
Reboot the system and check if this error goes away.
3.
If the error persists, replace the floppy drive.
4.
If the error still persists, the floppy drive controller on the
5.
system board may not be working. Replace the system
board.
2B1h Floppy drive B error
This error will be displayed if the floppy drive B failed the POST
test.
Actions You Can Tak
Check if power is connected to the floppy drive.
1.
Check if the floppy drive's cables are connected correctly.
2.
Reboot the system and check if this error goes away.
3.
If the error persists, replace the floppy drive.
4.
If the error still persists, the floppy drive controller on the
5.
system board may not be working. Replace the system
board.
2D0h System cache error -- cache disabled
This error will occur if the system processor L1/L2 caches failed
cache test during POST.
Actions You Can Take
Reboot the system and see if the error persists. If the
1.
error does not repeat, then this could be a soft error.
If the error does repeat, one of the system processors
2.

Advertisement

loading