Main menu
Operation
Vane · Louver · Vent.
(Lossnay)
High power
Comfort
Timer
Timer
Weekly timer
OU silent mode
Energy saving Restriction
Energy saving
Initial setting
Basic setting
Display setting
Operation setting
Maintenance
Error information
Filter information
Cleaning
OCH800A_126
Setting and display items
*3
Manual vane angle
3D i-See sensor
ON/OFF timer
*1
Auto-OFF timer
*1, *2
*1, *3
Temp. range
*2
Operation lock
Auto return
*2
Schedule
*1, *3
Main/Sub
Clock
Daylight saving time
Administrator password The administrator password is required to make the settings for the following items.
Main display
Display details
Contrast • Brightness
Language selection
Auto mode
Setback mode
Auto descending panel
Use to set the vane angle.
• Select a desired vane setting.
Use to turn ON/OFF the louver.
• Select a desired setting from ˝ON˝ and ˝OFF.˝
Use to set the amount of ventilation.
• Select a desired setting from ˝Off,˝ ˝Low,˝ and ˝High.˝
Use to reach the comfortable room temperature quickly.
• Units can be operated in the High-power mode for up to 30 minutes.
• Use to fix each vane angle.
Horizontal air direction
• Sets the horizontal airflow direction (vane) of each unit.
Use to set the following functions for 3D i-See sensor.
• Air distribution
• Energy saving option
• Seasonal airflow
Use to set the operation ON/OFF times.
• Time can be set in 5-minute increments.
Use to set the Auto-OFF time.
• Time can be set to a value from 30 to 240 in 10-minute increments.
Use to set the weekly operation ON/OFF times.
• Up to 8 operation patterns can be set for each day.
(Not valid when the ON/OFF timer is enabled.)
Use to set the time periods in which priority is given to quiet operation of outdoor units over
temperature control. Set the Start/Stop times for each day of the week.
• Select the desired silent level from ˝Normal,˝ ˝Middle,˝ and ˝Quiet.˝
Use to restrict the preset temperature range.
• Different temperature ranges can be set for different operation modes.
Use to lock selected functions.
• The locked functions cannot be operated.
Use to get the units to operate at the preset temperature after performing energy saving
operation for a specified time period.
• Time can be set to a value from 30 and 120 in 10-minute increments.
(This function will not be valid when the preset temperature ranges are restricted.)
Set the start/stop times to operate the units in the energy saving mode for
each day of the week, and set the energy saving rate.
• Up to 4 energy saving operation patterns can be set for each day.
• Time can be set in 5-minute increments.
• Energy saving rate can be set to a value from 0% or 50 to 90% in 10% increments.
When connecting 2 remote controllers, one of them needs to be designated as a sub
controller.
Use to set the current time.
Set the daylight saving time.
• Timer setting
• Energy saving setting
• Weekly timer setting
• Restriction setting
• Outdoor unit silent mode setting
Use to switch between ˝Full˝ and ˝Basic˝ modes for the Main display, and use to change
the background colors of the display to black.
Make the settings for the remote controller related items as necessary.
Clock: The initial settings are ˝Yes˝ and ˝24h˝ format.
Temperature: Set either Celsius (°C) or Fahrenheit (°F).
Room temp.: Set Show or Hide.
Auto mode: Set Auto mode display or Only Auto display.
Use to adjust screen contrast and brightness.
Use to select the desired language.
Whether or not to use Auto mode can be selected by using the button.
This setting is valid only when indoor units with Auto mode function are connected.
Whether or not to use the Setback mode can be selected by using the button.
This setting is valid only when indoor units with the Setback mode function are connected.
Use to check error information when an error occurs.
• Check code, error source, refrigerant address, model name, manufacturing number,
contact information (dealer's phone number) can be displayed.
(The model name, manufacturing number, and contact information need to be registered
in advance to be displayed.)
Use to check the filter status.
• The filter sign can be reset.
Use to lift and lower the auto descending panel (Optional parts).