E68
Checks to perform:
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J6-1/J6-2 and the
appliance body.
-(see fig. 6)-
Is the circuit open?
Y
E
S
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms
Fig. 15
Fig. 6
2010 SOI/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics for electronic controls EWM0931x
E68: Washing heating element leakage
Check that all the connectors are inserted correctly
Detach the connector
and measure between
the heating element
and the earth contact.
NO
- (see fig 15) -
Is the circuit open?
Check/replace the wiring and repeat the diagnostic cycle to
General
earthing
connection
Heating
element
∞
Ω
∞
Ω
NO
Y
E
S
check for any further alarms.
J14
J5
J4
GND
Fig. 4
If there are burns on the circuit
52/67
Run phase 8 of the
diagnostic cycle, drain water
from the tub. Replace the
heating element and repeat
the diagnostic cycle to
check for any further alarms.
J13
J8
J11
J10
J7
J6
∞
Ω
MAIN PCB
board, see page 65
599 72 97-24
E68