E54: Motor Relay Contacts Sticking - Electrolux EWM0931 Series Service Manual

Table of Contents

Advertisement

E54
Voltage value on the motor circuit even when this should not be operating
Checks to perform:
Measure between all the terminals of the
wiring connector J11-1 - J11-5 and the
appliance body - see page 47 - point 3
Is there any dispersion?- (see fig. 6) -
Y
E
S
Detach the connector from the motor and
measure between the terminals and the
motor casing.-(see fig. 10) -
Is there any dispersion?
Y
E
S
Replace the motor and repeat the diagnostic
cycle to check for any further alarms.
MAIN PCB
2010 SOI/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics for electronic controls EWM0931x

E54: Motor relay contacts sticking

Check that all the connectors are inserted correctly
Fig. 10
General earthing
Replace the circuit board and repeat the
diagnostic cycle to check for any further
NO
Check/replace the wiring and repeat the
diagnostic cycle to check for any further
NO
J14
J5
J4
GND
Fig. 4
connection
49/67
alarms.
alarms.
J11
J13
J10
J8
J6
If there are burns on the circuit
board, see page 65
599 72 97-24
E54
J7
Fig. 6