Before you finish
Remove the lancing device cap. Point the lancet away from you. Slide out the ejector to release the lancet.
If any of the error messages below appear on the display at any time, refer immediately to the Owner's Booklet, Chapter 7, Display and Error Messages.
The test strip may be damaged or not properly inserted. Remove and reinsert the test strip, or replace it if damaged.
Your blood glucose may be extremely high or a meter or a test strip error has occurred. If your test result matches how you feel, contact your healthcare professional immediately. If your test result does not match how you feel, repeat the blood glucose test. See the Owner's Booklet, Chapter 4, Unusual Blood Glucose Results. If the E-3 code still appears for your blood glucose test, your blood glucose result may be extremely high and above the system's reading range. Contact your healthcare professional immediately. If the second test result does not match how you feel, perform a control test with the control solution and a new test strip. If the control result is within the acceptable range, review the proper testing procedure and repeat the blood glucose test with a new test strip. If the control result is not within the acceptable range, see the Owner's Booklet, Chapter 2, Understanding Out-of-Range Control Results.
Not enough blood or control solution was drawn into the test strip for measurement or was applied after the test had started. Discard the test strip and repeat the blood glucose or control test.
Blood or control solution was applied to the test strip before the flashing drop symbol appeared on the display. Discard the test strip and repeat the blood glucose or control test.
An electronic error occurred, or in rare cases, a used test strip was removed and reinserted. Turn the meter off and on, or take the battery out for 20 seconds and reinsert it. Perform a blood glucose or control test.
The temperature is above or below the proper range for the system. Refer to the test strip package insert for system operating conditions. Move to an area with the appropriate conditions, wait 5 minutes, and repeat the blood glucose or control test. Do not artificially heat or cool the meter.
The battery is almost out of power. Change the battery now. If the message reappears after the battery has been replaced, remove the battery again, press any meter button, then reinsert the battery.
The time and date settings may be incorrect. Make sure the time and date are correct and adjust, if necessary.
NOTE
Contact the Accu-Chek Customer Care Service Center at 1-800-858-8072 if the error message continues.
Roche Diabetes Care, Inc.
9115 Hague Road
Indianapolis, IN 46256
www.accu-chek.com
ACCU-CHEK, ACCU-CHEK AVIVA, and SOFTCLIX are trademarks of Roche.
© 2019 Roche Diabetes Care
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Accu-Chek Aviva Plus - Blood Glucose Monitoring System Quick Start Guide
Advertisement
Thank you! Your question has been received!
Need Assistance?
Do you have a question about the Aviva Plus that isn't answered in the manual? Leave your question here.