Adapting Microwave Blower - Bosch HMVP052U Installation Manual

Hide thumbs Also See for HMVP052U:
Table of Contents

Advertisement

Available languages

Available languages

Adapting microwave blower

This microwave is shipped assembled for Room Venting
Installation. The blower unit is already in place and must
not to be adapted.
Adapting microwave blower for roof venting
Remove and save the screws holding the blower
1.
motor and the blower plate. Lift up the blower plate
and put it aside.
Carefully pull out the blower unit and rotate 90º so that
2.
fan blade openings are facing out the top of the
microwave.
Place the blower unit back into the opening.
3.
CAUTION
9
Do not pull or stretch the blower unit wiring. Make
sure the wires are not pinched, and that they are
properly secured.
Replace the blower plate and secure with the screws
4.
removed in step 1.
Attach the exhaust adapter to the top of the blower
5.
plate by sliding it into the guides. Push in securely until
it is in the locking tabs. Make sure the damper hinge
swings freely.
Adapting microwave blower for wall venting
Remove and save the screws holding the blower
1.
motor and the blower plate. Lift up the blower plate
and put it aside.
Carefully pull out the blower unit and rotate 90º so that
2.
fan blade openings are facing out the top of the
microwave.
Rotate the blower unit counterclockwise 180º.
3.
11

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

800 seriesHmv5052uHmv8052u500 series

Table of Contents