Bosch BGH96M060B3B Installation Instructions Manual page 41

96% afue condensing gas furnace
Table of Contents

Advertisement

Input
Output
MBH
kW
MBH
60B3
17.6
57
80B3
23.4
76
80C4
23.4
76
100C5
29.3
95
100D5
29.3
95
120D5
35.2
106.5
Table 18
Ratings & Physical / Electrical Data
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
Optional Switch Positions
DIP Switch (SW)
S1-1
ON
OFF
ON
Table 19
W2 Delay
* The factory default settings
DIP Switch (SW)
S2-1
OFF
ON
OFF
ON
Table 20
Heat Off Delay
* The factory default settings
DIP Switch (SW)
S2-3
OFF
ON
OFF
ON
Table 21
Cool Off Delay
* The factory default settings
Bosch 96% AFUE Condensing Gas Furnace - BTC 770503101 J (06.2023)
Nominal
MAX. Unit
Airflow
Amps
kW
CFM
16.7
1200
8
22.3
1200
8
22.3
1600
7.8
27.8
2000
11.5
27.8
2000
10.5
31.2
2000
10.5
NOMINAL
(MINUTES)
S1-2
OFF
10
ON
AUTO
ON
20
NOMINAL
(SECONDS)
S2-2
OFF
90*
OFF
120
ON
150
ON
180
NOMINAL
(SECONDS)
S2-4
OFF
60*
OFF
90
ON
120
ON
150
Air Temp. Rise
Over-Current
AFUE
° F
° C
96
30-60
17-33
96
35-65
19-36
96
35-65
19-36
96
35-65
19-36
96
35-65
19-36
95
40-70
22-39
Installation Instructions
Max.
Max. Outlet Air Temp
Min. Wire Size
Protection
(AWG) @ 75 ft
Amps
15
14
160
15
14
165
15
14
165
20
14
165
20
14
165
20
14
170
° F
° C
71
74
74
74
74
77
| 41