Bosch BGH96M060B3B Installation Instructions Manual page 21

96% afue condensing gas furnace
Table of Contents

Advertisement

NOTICE:
In this installation, hoses connecting between ports of
f
overflow protection pressure switch (overflow switch)
and pressure tabs on the condensate collector box MUST
be switched. The overflow switch has two ports, which is
different from two other regular pressure switches that
have only one port. Make sure that black port (positive)
is connected to the lower position tap on condensate
collector box and gray port (negative) to higher tap of
condensate box. Connecting incorrectly will result in
failure to protect condensate overflow. See Fig. 19.
Upflow & Horizontal Right side
A to + P1(black port)
B to – P2(grey port)
Horizontal Le side
A to – P2(grey port)
B to + P1(black port)
B
Condensate Collector Box
Figure 19
NOTICE:
Two pressure switches (one port type switches) should
f
be relocated to other side of furnace side panel to ensure
pressure switches are above water tap of condensate
collector box.
Bosch 96% AFUE Condensing Gas Furnace - BTC 770503101 J (06.2023)
+
_
A
Installation Instructions
| 21

Hide quick links:

Advertisement

Table of Contents