Specifications, Spare Parts And References; Physical And Operational Specifications - GE BAKER HUGHES Masoneilan SVi 1000 Quick Start Manual

Table of Contents

Advertisement

Appendix D. Specifications, Spare Parts and
References

Physical and Operational Specifications

This section provides the physical and operational specifications for the SVi1000. Specifications
are subject to change without notice
Parameter
Operating Temperature Limits
Storage Temperature Limits
Temperature Effect
Supply Pressure Effect
Operating Relative Humidity
Storage Relative Humidity
Humidity Effect
Electromagnetic Compatibility
Electrostatic
Fast Transient Burst
Vibration Influence
Measured at SVi1000 Housing
Housing
Magnetic Field Influence
© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
Table 7: Environmental Specifications
-40 °F to 185 °F (-40 °C to 85 °C)
-58 °F to 200 °F (-50 °C to 93 °C)
< 0.005% / °F typical; -40 °F to 180 °F (< 0.01% / °C typ-
ical; -40 °C to 82 °C)
0.05% per psi (.73% per bar)
5 to 100% non-condensing
0 to 100% non-condensing
Less than 0.2% after 2 days at 104 °F (40 °C), 95% Rela-
tive Humidity.
IEC 61514 Industrial-Process Control systems -
methods of evaluating the performance of intelli-
gent valve positioners with pneumatic outputs.
IEC 61326 Electrical equipment for measurement,
control and laboratory use - EMC requirements.
No effect at 2 kV (Coupling clamp EN61000-4-4 or
IEC1000-4-4).
4 mm at 5 - 15 Hz - Negligible
2 G at 15 - 150 Hz Less than 2 % of span
1 G at 150 - 2000 Hz - Less than 2% of span
Tropicalized with positive pressure
Negligible at 100 A/m 50/60 Hz (EN61000-4-8)
CE MARK
The SVi1000 conforms to the requirements of the ATEX
94/9/EC and EMC 2014/30/EU directives.
Storage & Transport (Packaged)
Masoneilan SVi1000 Positioner Quick Start Guide =| 65

Advertisement

Table of Contents
loading