GE BAKER HUGHES Masoneilan SVi 1000 Quick Start Manual page 28

Table of Contents

Advertisement

3. Select mounting hole for the stroke of the valve. Unless otherwise specified, the
SVi1000 mounting assumes that the actuator is in the normal upright position.
The mounting hole in the slotted opening of the mounting bracket must be left
when facing the actuator, with the actuator in the upright position.
Table 3: Reciprocating Valve Mounting Hole and Turnbuckle Length
Actuator Size
Masoneilan
87/88
6 and 10
10
10
16
16
16
23
23
23
28 | =BHGE
Stroke
0.5 - 0.8"
(12.7 - 20.32 mm)
0.5 - 0.8"
(12.7 - 20.32 mm)
>0.8 – 1.5"
(20.32 - 41.5 mm)
0.5 - 0.8"
(12.7 - 20.32 mm)
>0.8 – 1.5"
(20.32 - 41.5 mm)
>1.5 – 2.5"
(41.5 - 63.5 mm)
0.5 - 0.8"
(12.7 - 20.32 mm)
>0.8 – 1.5"
(20.32 - 41.5 mm)
>1.5 – 2.5"
(41.5 - 63.5 mm)
Mounting
Lever
Hole
A
A
A
A
B
B
B
A
C
B
D
C
B
A
C
B
D
C
© 2019 Baker Hughes, a GE company, LLC. All rights reserved.
Turnbuckle
Hole
Length
1.25"
(31.75 mm)
1.25"
(31.75 mm)
1.25"
(31.75 mm)
2.90"
(73.66 mm)
2.90"
(73.66 mm)
2.90"
(73.66 mm)
5.25"
(133.35 mm)
5.25"
(133.35 mm)
5.25"
(133.35 mm)

Advertisement

Table of Contents
loading

Table of Contents