Product Details; Standard Delivery; Technical Data - Bosch MP100 Installation Instructions Manual

Skilled labour
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 7
8 |

Product details

▶ The product requires different voltages.
Do not connect the extra-low voltage side to the mains
voltage or vice versa.
▶ Also observe connection diagrams of other system
components.
Handover to the end user
When handing over the heating system, explain the operating
conditions to the user.
▶ Explain how to operate the heating system, with particular
emphasis on all safety-related actions.
▶ Explain that conversions or maintenance must only be
carried out by a competent person.
▶ Point out the need for inspections and maintenance for
safe and environmentally friendly operation.
▶ The installation and operating instructions must be given to
the end user for keeping.
Damage caused by frost
The system can freeze if it is switched off:
▶ Observe the notices regarding frost protection.
▶ Due to the additional functions, e.g. DHW heating or anti-
seizing protection, the system should always be left on.
▶ Correct any faults immediately.
2
Product details
The module serves to activate a swimming pool connected
to a heat pump with a EMS 2/EMS plus interface.
The module serves to determine the swimming pool
temperature and activate a mixer as required by the heat
pump.
Anti-seizing function: the connected mixing valve actuator
is monitored and run automatically for a short period after
24 hours of downtime. This prevents the mixer from
seizing up.
A maximum of one MP100 is permitted in a system,
irrespective of the number of other BUS nodes.
2.1

Standard delivery

Fig. 1, page 77:
[1] Module
[2] Bag with installation accessories
[3] Swimming pool temperature sensor TC1 installation set
[4] Installation instructions
6 720 812 220 (2014/06)
2.2

Technical data

Design and operation of this product conform to
European Directives and the supplementary
national requirements. Its conformity is
demonstrated by the CE marking .
Technical data
Measurements
(W × H × D)
Maximum conductor
cross-section
230 V terminal
Extra-low voltage
terminal
Rated voltages
BUS
Module power supply
User interface
Mixer
Circuit breaker
BUS interface
Power consumption on
– standby
Maximum output
Per connection
(VC1)
Temperature sensor
capturing range
lower fault limit
display range
upper fault limit
Permissible ambient
temperature
IP rating
For installation in
heat source
For wall-mounted
installation
Protection class
ID no.
Table 2
151 × 184 × 61 mm (further
dimensions  Fig. 2, page 77)
2
2.5 mm
2
1.5 mm
15 V DC (reverse-polarity-
protected)
230 V AC, 50 Hz
15 V DC (reverse-polarity-
protected)
230 V AC, 50 Hz
230 V, 5 AT
EMS 2/EMS plus
< 1 W
100 W
< – 10 °C
0 ... 100 °C
> 125 °C
0 ... 60 °C
Determined by the IP rating of
the heat appliance
IP 44
I
Data plate ( Fig. 15, page 82)