2.3 Installation of the sensor base

To ensure safe installation:
 Do not install the sensor core (black part) into the sensor base
(grey part) before the final installation of the sensor base on the
ground.
 Do not screw the sensor base on the ground!
 Do not drill holes in the base!
 Do not bring a magnet near the PLS (this would power-on the
device).
 Avoid uninstalling and reinstalling the sensor core after the initial
installation into the sensor base.
 Do not open the sensor core!
The sensor base must be fixed to the ground (substrate such as concrete, asphalt) with a two-component adhesive
from a leading supplier (e.g., DELO®, 3M®, ...).
Customers have reported good experience with the following adhesive: DELO®-PUR 9692 (universal 2-component
polyurethane adhesive available in 50 ml and 200 ml cartridges).

Required material for installing the parking lot sensor

Figure 2
Material for attachment
1
Disposable gloves (protection against contact with adhesive)
2
Two-component adhesive
3
Adhesive press (these differ, depending on the cartridge size)
4
Mixing tube
5
Tape rule
6
Sensor base
7
Sensor core (sensor)
8
T20 screw
9
Sensor cap (sensor sealing cap)
10 Appropriate tool to clean ground surface (e.g., broom, air blower)