Information On The Indoor Unit; Declaration Of Conformity; Type Plate; Functional Principle - Bosch Compress 3400i AWS Installation Manual

Indoor unit for air to water heat pump
Hide thumbs Also See for Compress 3400i AWS:
Table of Contents

Advertisement

3.2

Information on the indoor unit

The AWS E indoor units are intended for installation inside the building
and for connection to the outdoor unit.
Possible combinations of indoor unit with different outdoor units:
AWS E
CS3400iAWS 10 E
CS3400iAWS 10 E
CS3400iAWS 10 E
CS3400iAWS 10 E
1) A 5/8" to 1/2" adapter is provided with CS3400iAWS 4 OR-S
Table 5 Possible combinations
AWS E is equipped with an integrated electric booster heater.
3.3

Declaration of Conformity

The design and operating characteristics of this product comply with the
British, European and supplementary national requirements.
The UKCA and CE markings declare that the product
complies with all the applicable British and
European legislation, which is stipulated by
attaching these markings.
You can request the complete text of the Declaration of Conformity from
the UK address indicated in this document.
3.4

Type plate

The type plate of the indoor unit is on the side of the appliance. It
contains information on the part number and serial number as well as the
date of manufacture of the device.
3.5

Functional principle

The function is based on the demand-actuated control of the compressor
output and, if needed, by switching on the integrated electric booster
heater via the indoor unit. The control unit controls the outdoor unit
depending on the set heating curve.
If the outdoor unit is unable to satisfy the heat energy demand of the
house, the indoor unit automatically starts the integrated electric
booster heater which produces the desired temperature in the house
together with the outdoor unit.
The DHW heating is controlled via the TW1 sensor in the DHW cylinder.
During the heat-up phase of the DHW cylinder, the heating mode of the
heating system is temporarily switched off via a 3-way valve. Once the
DHW cylinder is heated up, heating mode is resumed by the outdoor
unit.
Heating and DHW mode when the outdoor unit is deactivated
When the outdoor temperature is below –20 °C (approximately) or
exceeds 45 °C (approximately), the outdoor unit is automatically turned
off and is unable to produce any heat. In this case, the integrated electric
booster heater of the indoor unit adopts the heating and DHW mode.
Compress 3400i AWS – 6721852066 (2023/01)
CS3400iAWS
1)
CS3400iAWS 4 OR-S
CS3400iAWS 6 OR-S
CS3400iAWS 8 OR-S
CS3400iAWS 10 OR-S
3.6

Product overview

1
2
3
8
7
13
Fig. 3
Components and pipework connections of the indoor unit with
electric booster heater (views with drip tray)
[1]
Automatic air vent valve (VL1)
[2]
Electric booster heater
[3]
Pressure gauge
[4]
Installer module
[5]
Reset of the overheating protection
[6]
Primary circulation pump (PC0)
[7]
Flow to the heating system
[8]
Drain of the pressure relief valve and condensates
[9]
Return from the heating system
[10] Cable feed for power supply
[11] Cable feed for sensor, CAN-BUS and EMS BUS
[12] Refrigerant out to outdoor unit (liquid)
[13] Refrigerant in from outdoor unit (gas)
Product description
9
10
12
001004822-001
4
5
6
11
7