11.3.4 System with integrated booster heater, DHW and heating circuit with or without mixing valve and with bypass

PW2
TW1
CW1
Fig. 33 Outdoor unit with indoor unit, DHW and one or more heating circuits
[1]Installed in the indoor unit
[4] Mounted in the station or on the wall
[5] Mounted on the wall
PC1 and bypass are required in this hydraulic system ( Chapter
11.3.2).
Compress 3400i AWS – 6721852066 (2023/01)
HPC410
SEC 20
CR 10 H
1
1
5
T
T
PC1
T0
B
M
A
400 V AC
AB
VW1
MK2
IDU AWS E
CR 10 H
MM 100
5
4
2
MC1
T
T
TC1
PC1
M
VC1
V
T1
400 /230 V AC
CS3400i AWS
Technical information
6 720 878 476-01.1T