Steam Heated Boiling Pans, 400V 3N~50Hz; Electrically Heated Boiling Pans 400V 3N~50Hz* And Option Ice Water Cooling; Steam Heated Boiling Pans 400V 3N~50Hz* And Option Ice Water Cooling - Electrolux SMART Installation Instructions Manual

Boiling pans with tilting height 600mm
Hide thumbs Also See for SMART:
Table of Contents

Advertisement

11.4 Steam heated boiling pans, 400V 3N~50Hz*

PNC
model
232237
Sm6V50S
232238
Sm6V100S
232242
Sm6P100S
232234
Sm6B150S
232239
Sm6V150S
232243
Sm6P150S
232235
Sm6B200S
232240
Sm6V200S
232244
Sm6P200S
232236
Sm6B300S
232241
Sm6V300S
232245
Sm6P300S
* The connection lead may be at most 6 mm² to have room in the connection terminals.
11.5 Electrically heated boiling pans 400V 3N~50Hz* and option ice water
cooling
PNC
model
232223 + 928153 SV6I50
232149 + 928164 SV6I80
232224 + 928154 SV6I100
232228 + 928154 SP6I100
232225 + 928155 SV6I150
232229 + 928155 SP6I150
232226 + 928156 SV6I200
232230 + 928156 SP6I200
232227 + 928157 SV6I300
232231 + 928157 SP6I300
* The connection lead may be at most 32 mm² to have room in the connection terminals.
11.6
Steam heated boiling pans 400V 3N~50Hz* and option ice water cooling on request
model
Volume
Heating
L
kg/h
SV6I50S
50
24
SV6I100S
100
36
SP6I100S
100
36
SV6I150S
150
47
SP6I150S
150
47
SV6I200S
200
59
SP6I200S
200
59
SV6I300S
300
78
SP6I300S
300
78
* The connection lead may be at most 6 mm² to have room in the connection terminals.
18
Tilting
Volume
Heating
motor
L
kg/h
kW
50
24
0.19
100
36
0.19
100
36
0.19
150
47
0.37
150
47
0.37
150
47
0.37
200
59
0.37
200
59
0.37
200
59
0.37
300
78
0.37
300
78
0.37
300
78
0.37
Tilting
Volume
Heating
motor
L
kW
kW
50
15.0
0.19
80
22.5
0.19
100
22.5
0.19
100
22.5
0.19
150
30.0
0.37
150
30.0
0.37
200
37.5
0.37
200
37.5
0.37
300
50.0
0.37
300
50.0
0.37
Tilting
Agitator
motor
motor
kW
kW
0.19
0.75
0.19
1.5
0.19
2.2
0.37
1.5
0.37
2.2
0.37
2.2
0.37
3.0
0.37
2.2
0.37
3.0
DOC N° ST0 9183-02
INSTALLATION INSTRUCTIONS | SmART LINE BOILINg PAN
Agitator
Total
Phase
motor
power
current
kW
kW
0.75
1.0
1.5
1.7
2.2
2.4
-
0.5
1.5
2.0
2.2
2.8
-
0.5
2.2
2.8
3.0
3.6
-
0.5
2.2
2.8
3.0
3.6
Agitator
Drainwater
Total
motor
pump
power
kW
A
kW
0.75
0.51
15.8
0.75
0.51
23.3
1.5
0.51
24.0
2.2
0.51
24.7
1.5
0.51
31.5
2.2
0.51
32.2
2.2
0.51
39.0
3.0
0.51
40.5
2.2
0.51
52.2
3.0
0.51
53.0
Drainwater
max. Phase
pump
Total power
current
A
kW
0.51
1.0
0.51
1.7
0.51
2.4
0.51
2.0
0.51
2.8
0.51
2.8
0.51
3.6
0.51
2.8
0.51
3.6
max.
Rec.
max.
fuse
fuse
A
A
A
7
10
16
9
16
20
9
16
20
3
10
16
9
16
20
9
16
20
3
10
16
10
16
20
14
16
20
3
10
16
10
16
20
14
16
20
max.
Phase
Rec.
max.
current
fuse
fuse
A
A
A
27
32
50
38
40
50
39
40
50
39
40
50
50
50
63
50
50
63
62
63
100
66
80
100
80
80
100
84
100
100
Rec. fuse
max. fuse
A
A
A
7
10
16
9
16
20
9
16
20
9
16
20
9
16
20
10
16
20
14
16
20
10
16
20
14
16
20
EN | 10-2018