Parameter description
6.3 Vector Control Parameters
Code
Description
Speed loop
F3.00
proportional
gain 1
Speed loop
F3.01
integral time 1
Switching
F3.02
frequency 1
Speed loop
F3.03
proportional
gain 2
Speed loop
F3.04
integral time 2
Switching
F3.05
frequency 2
Speed loop
F3.06
filter time
constant
Current loop
F3.07
proportional
coefficient
Current loop
F3.08
integral
coefficient
VC Slip
F3.09
compensation
F3.10
Torque control
Torque digital
F3.11
setting
SINAMICS V50 converter
36
Operating Instructions, 04/2022, FW V1.0, A5E44777205B AB
Setting range
1~3000
1~3000
0.0~60.00Hz
1~3000
1~3000
0.0~60.00Hz
0~500ms
0~6000
0~6000
0.0~200.0%
0: Torque
control Disabled
1: Torque
digital setting
(F3.11)
2: AI1
3: AI2
4: Pulse
5: Comm.
0.0~200.0%
Default
Modify
1000
О
300
о
5.00Hz
о
800
о
200
о
10.00Hz
о
3ms
о
3000
о
1500
о
100.00%
о
0
о
50.00%
о
Modbus
Address
0400H
0401H
0402H
0403H
0404H
0405H
0406H
0407H
0408H
0409H
040AH
040BH

Advertisement