LG LGES-5048 User Manual page 16

Hide thumbs Also See for LGES-5048:
Table of Contents

Advertisement

1
Prepare the terminals and AC cables according to the right table.
2
Put AC cable through terminal cover as
shown in the figure.
Note: Please use the terminals in accessory
box.
3
Press the 6 connectors on cable conductor core tightly.
Note: Make sure cable jacket is not locked within the connector.
4
Tightening torque
2.0-2.5N·m
1. Connect the assembled AC cables into AC terminals with fastening torque about 2.0-2.5N·m.
Note: Connect back-up terminals before connecting on-grid terminals. Make sure it is not connected
to the wrong side.
2. Lock the cover and screw the cap.
A
C
B
Grade
A
D
B
C
D
Insulator
Screw Cap
Single Hole Seal Ring
Cable
13
Description
Value
Outside diameter
13-18 mm
Separated wire length
20-25 mm
Conductor wire length
7-9 mm
Conductor core section
4-6 mm
AC Cover
Connection
Terminal
2