E664
Cause:
Two or more external input functions which may not be combined are set
in one file. The following combinations are not allowed:
Character entry by SIN command/Register function (registered
characters switching via I/O connector)
Character entry by SIN command/Marking offset via I/O signal
Register function (registered characters switching via I/O
connector)/Marking offset by SEO command
Linking of image processing devices/Trigger mode "Continuous
trigger"
LP-RC, LP-RF, LP-RV:
Linking of image processing devices/TARGET DETECTION IN (X7)
input of TERMINAL connector
Remedy:
Delete any one of these functions from the file.
E665
Cause:
The marking data include characters that cannot be converted into 2D
code.
Remedy:
Use characters which can be converted into 2D code.
For QR Code, change the mode setting. For Data Matrix, change the
character type setting. For PDF417, change the compaction mode
setting.
E666
Cause:
The 2D code cannot be generated with the specified settings.
The number of characters exceeds the upper limit of the selected 2D
code.
Remedy:
Check the code settings and the number of characters.
E667
Cause:
The filling pattern specified for the 2D code is not available in the 2D
code font (font number: 2D).
Remedy:
Change the filling pattern.