Mitsubishi Electric MELDAS 600M Series Instruction Manual page 505

Table of Contents

Advertisement

4.6 Program warnings (PRW
No.
PRW0001 Overlap address
PRW0002 Overlap G code
PRW0003 Ignored G code
PRW0004 Unused address
PRW0005 Ref point ret in
PRW0006 No end point
PRW0007 Cylinder mode
Downloaded from
ManualsNet.com
CHAPTER 4 APPENDICES
Appendix 4. Warning Messages
Message
Because the No. of addresses
exists
that can be simultaneously
commanded in one block was
exceeded, the previously
designated address was
ignored.
No. of addresses that can be
simultaneously commanded in
one block :
M = Max. 4 addresses.
Other than M = 1 address
Because several G codes were
exists
commanded in the same group,
the previously designated G
code was ignored.
A G code exists that was
exists
ignored due to a G code priority
order check.
An address exists that was not
exists
used in the program block.
Reference point return was
pattern rot
attempted while rotating the
figure.
There is no end point coordinate
operation in arc
command for the R-designated
arc.
A command illegal for the
warning
cylindrical mode was issued.
search engine
)
Details
• Reconsider the program.
• Reconsider the program.
• Reconsider the program.
• Reconsider the program.
• Reconsider the program.
• Reconsider the program.
• Reconsider the program.
IV – 63
Remedy