Siemens SICHARGE UC Operating Instructions Manual page 12

Table of Contents

Advertisement

SICHARGE UC Dispenser UL | Operating Instructions
Protection against electromagnetic fields
The electromagnetic emission in the charging station meets the requirements of the UL 2202 standard:
Note
Radio interferences
The operation of this device can cause radio interferences in residential areas.
Protection against ingress of liquid
The protection standard of the cabinet protects the SICHARGE UC dispenser from ingress of water
splashing against it from all directions. In particular, the NEMA 3R enclosure prevents the ingress of
precipitation and any liquid not under pressure that comes into contact with the cabinet surface.
In addition, protect the SICHARGE UC dispenser from liquids hitting the cabinet surface under pressure:
• Never use a pressure washer or steam cleaner to clean the SICHARGE UC dispenser.
• Set up the SICHARGE UC dispenser at a flood-proof location.
WARNING
Electric shock due to ingress of liquid.
Powerful water jets or flooding can cause the liquid to enter the SICHARGE UC dispenser. Moisture
or liquid inside the SICHARGE UC dispenser can lead to electric shock.
Conduct the following safety measures when there is a chance that liquid may have entered the
SICHARGE UC dispenser:
• Shut down the SICHARGE UC dispenser by disconnecting the power supply to the SICHARGE UC
charging station.
• Qualified personnel must dry the SICHARGE UC dispenser and check it for damages.
Protection against unauthorized opening
A lock system protects the SICHARGE UC dispenser from unauthorized opening of the device door.
• Only make the key available to authorized personnel for work performed inside the SICHARGE UC dispenser.
• Do not leave the SICHARGE UC dispenser unattended when the device door is open.