Internet Address
Retransmission Timer / Retransmission Counter
Module Name
External ARP Table
Normally, the internet address is entered in the SK table of the controller.
Older versions of the SK500 or the ZS400 though do not support this entry. If
these modules are used, the IP address can be specified via the terminal.
The address must be entered in the following form:
number.numbers.numbers.numbers
Editor utilities are:
Delete
deletes the last entry
D
Return
finishes the entry
D
Escape
aborts the entry without storing the entered data
D
These two values are normally specified by the configuration file. For com-
missioning or when working without the configuration file, the default values
can be changed via a terminal.
Editor utilities are:
Delete
deletes the last entry
D
Return
finishes the entry
D
Escape
aborts the entry without storing the entered data
D
The input of the module name is initialized with the N-button. The module
name can have a maximum of 31 characters.
As characters, the ASCII characters >0x20 and < 0x7f are applicable.
Editor utilities are:
Delete
deletes the last entry
D
Return
finishes the entry
D
Escape
aborts the entry without storing the entered data
D
The external ARP table can be output via the A-button. The Ethernet ad-
dresses of the network nodes that have established a connection with the
COM-E module are stored in this ring memory with 64 entries.
Example:
ARP requests:
IP: 142.2.42.96, Eth: 00--60--08--44--74--11
IP: 142.2.36.86, Eth: 00--60--08--34--91--30
1070 072 196-101 (00.06) GB