1.3

Warning Label

Product/warning label and Battery Control Unit's traceability label are behind the front cover.
The front cover opens by turning the front cover handle counterclockwise. Battery Modules'
traceability labels are attached to the side of the Battery Modules.
1. Product/Warning Label
2. Traceability label
2-1. Battery Control Unit
2-2. Battery Module
EH153064P8S7DMA
SH077064P8S7BMA
○○○○○○○○○○
○○○○○○○○○○A
1.4 Qualifi ed Personnel
This guide for the tasks and procedures described herein is intended for use by skilled staff
only. A skilled staff is defi ned as a trained and qualifi ed electrician or installer who has all of
the following skills and experience:
• Knowledge of the functional principles and operation of on-grid and off -grid
(backup) systems
• Knowledge of the dangers and risks associated with installing and using electrical
devices and acceptable mitigation methods
• Knowledge of the installation of electrical devices
• Knowledge of and adherence to this guide and all safety precautions and best
practices
• Qualifi cation specifi ed in battery warranty fi le
: BLG RESU-certifi cation in the battery website
: Knowledge of local installation standards
: Electrical license for battery installation required by the country or state
• Repair the battery by disassembly is possible only at the LG Service Center or by
a person who is specially authorized separately from the installation qualifi cation

2 Product Introduction

2.1 Technical Data

2.1.1
Part Number
Weight
1) Battery pack weights may vary slightly.
2.1.2
Electrical Characteristics
Usable Energy
Battery Capacity
Voltage Range
Absolute Max. Voltage
Max. Current (charging/discharging) 14.3A @ 350V
Max. Power (charging/discharging)
Peak Power
Peak Current (only discharging)
Communication Interface
DC Disconnect
SH077064P8S7BMA
Connection Method
○○○○○○○○○○B
User Interface
Operating Conditions
Installation Location
Operating Temperature
Operating Temperature
(Recommended)
Storage Temperature
Humidity
Altitude
Cooling Strategy
Certifi cation
Safety
Emissions
Hazardous Materials Classifi cation
Transportation
Ingress Rating
※ Test Conditions: Temperature 25°C/77°F, at the beginning of life.
※ Energy is measured under specifi c conditions from LG Electronics (0.3CPCV/0.3CP).
1) Value for battery pack only. Maximal usable energy at the AC output may vary by condition,
such as inverter effi ciency, confi guration and temperature.
2) Peak current excludes repeated short duration (less than 10 sec. of current pattern).

Dimensions and Weight

BLG RESU10HP
TLB00983101
Width
504 mm (19.8")
Height
817 mm (32.2")
Depth
295 mm (11.6")
1)
111 kg (244 lbs)

Performance

1)
9.6 kWh
64.1 Ah
350 to 450 VDC
595 VDC
5 kW
2)
(only discharging)
7 kW for 10 sec.
20.9 A for 10 sec.
RS485/ CAN
Circuit Breaker
Spring Type Connector
LEDs for Normal and Fault Operation
Indoor/Outdoor
charge
discharge
59°F to 86°F (15°C to 30°C)
-22°F to 140°F (-30°C to 60°C), acceptable for 7
days in total
-4°F to 113°F (-20°C to 45°C), acceptable for the
fi rst 6 months
-4°F to 86°F (-20°C to 30°C), acceptable for months
7~12
5% to 95%
Max. 6,562 ft (2,000 m)
Natural Convection
Cell
Battery
Pack
14°F to 122°F (-10°C to 50°C)
-4°F to 122°F (-20°C to 50°C)
UL1642
CE / RCM / IEC 62619 / UL1973 /
IEC62477-1
FCC
Class 9
UN38.3
IP55