decreasing and the indoor fan is fixed at low speed. Anti-cold
wind function takes priority.
• The operating time for sleep mode is 7 hours, after that, the unit
exits this mode and switches off.
• The timer setting is available in this mode.

3.1.11 Auto-Restart function

• The indoor unit has an auto-restart module that allows the unit to
restart automatically. The module automatically stores the current
settings (except swing setting). In case of a power break, those
settings will be saved automatically within 3 minutes after power
returns.
• If the unit was in forced cooling mode, it will run in this mode for
30 minutes and turn to auto mode with temperature set to 24°C.
• If there is a power failure while the unit is running, the compressor
starts 3 minutes after the unit restarts. If the unit was already off
before the power failure, the compressor starts 1 minute after the
unit restarts.

3.1.12 Refrigerant Leakage Detection

With this new technology, the display area will show "EC" when the
outdoor unit detects refrigerant leakage. This feature is only active for
cooling mode and T2 (evaporator coil temperature) will be measured.
3.1.13 8°C Heating (Optional)
In heating mode, the temperature can be set to as low as 8°C, preventing
the indoor area from freezing if unoccupied during severe cold weather.

3.1.14 Self clean (Optional)

• If you press "Self Clean" during cooling or drying mode:
• For cooling models, the indoor unit will run in low fan mode for a
certain time, then ceases operation.
• For heat pump models, the indoor unit will run in fan-only mode,
then low heat, and finally in fan- only mode.
• Self Clean keeps the indoor unit dry and prevents mold growth.

3.1.15 Follow me (Optional)

• If you press "Follow Me" on the remote, the indoor unit will beep.
This indicates that the function is active.
• Once active, the remote control will send a signal every 3 minutes,
with no beeps. The unit automatically sets the temperature accord-
ing to the measurements from the remote control sensor.
• The unit will only change modes if the information from the remote
control makes it necessary, not from the unit's temperature setting.
• If the unit does not receive a signal for 7 minutes or you press
"Follow Me," the function will be deactivated. The unit regulates
temperature based on its own sensor and settings.

3.1.16 Silence (Optional)

Press "Silence" on the remote control to enable the SILENCE function.
While this function is active, the compressor frequency is maintained
at a lower level than F2. The indoor unit will run at faint breeze, which
reduces noise to the lowest possible level.

3.1.17 Information Inquiry

• To enter information inquiry status, complete the following proce-
dure within ten seconds:
• Press LED 3 times.
• Press SWING 3 times.
• If you are successful, you will hear beeps for two seconds.
CLIMATE 5000 RAC SINGLE SPLIT (R32) – 6720894076 (2019/08)
• Use the LED and SWING buttons to cycle through information
displayed.
• Pressing LED will display the next code in the sequence. Pressing
SWING will show the previous.
• The following table shows information codes. The screen will display
this code for two seconds, then the information for 25 seconds.
Product Features