Hitachi CP-WU5500 User Manual page 39

Hide thumbs Also See for CP-WU5500:
Table of Contents

Advertisement

7. Troubleshooting
(continued)
Phenomenon
The STACK
menu does not
work.
The projector
does not respond
to the remote
control.
The images are
either out of
focus or not well-
superimposed.
The images
from the two
projectors do not
superimposed
even after
performing fine
adjustment.
If you require more information on Instant Stack, please consult your dealer.
Cases not involving a machine defect
The settings on the projectors are not set
for the Intellectual Stack feature.
Check the following settings on the Main and
Sub projectors.
- STANDBY MODE in SETUP menu:
NORMAL
- COMMUNICATION TYPE under
COMMUNICATION in SERVICE menu:
OFF
- STACK LOCK in SECURITY menu: OFF
The remote control is pointed at the Sub
projector.
When operating in Intellectual Stack, only
the Main projector is capable of receiving the
remote control signals. Therefore, point at the
Main projector when using the remote control.
The two images are not superimposed
correctly.
Adjust the ZOOM ring, VERTICAL adjuster,
HORIZONTAL adjuster and the FOCUS ring
to superimpose the images.
If necessary, adjust PERFECT FIT and
KEYSTONE as well.
There are some adjustment differences in
the two images.
Try to resolve the problem with the following
measures.
- Press the AUTO button on the remote
control or execute AUTO ADJUST
EXECUTE on each of the projectors.
- Adjust H POSITION and V POSITION on
each of the projectors.
- Check the RESOLUTION setting in the
INPUT menu, and change to the same
setting if the setting differs between Main
and Sub.
Troubleshooting
Reference
page
6
3
7
15
Operating Guide
→ Using the
automatic
adjustment feature
→ IMAGE menu
→ AUTO ADJUST
EXECUTE,
H POSITION or
V POSITION
→ INPUT menu
→ RESOLUTION
39