Firmware Update Via "Fwupdate - Bosch Rexroth PSI 6 Series Operating Instructions Manual

Weld timer with medium-frequency inverter
Hide thumbs Also See for Rexroth PSI 6 Series:
Table of Contents

Advertisement

Available languages

Available languages

1070080028 / 08
|
PSI 6xxx
10.3.3

Firmware update via "FWUpdate"

Check the firmware version using the programming terminal (BOS).
12.
For firmware update of all timers via the Ethernet field bus interface.
The following is needed to perform a firmware update
• a PC with the "FWUpdate" software installed,
• a working connection to the PC via the Ethernet field bus interface.
• a BOS database installed on the PC with a valid timer reference
(BOS 6000 installed) and
• the firmware as a *.hex file.
"
Proceed as follows:
Start the "FWUpdate" software.
1.
When the software is started, it will search for a valid timer reference
(is read from the BOS6000 database) and show you all properly lin­
ked timers in tabular format:
Use the "SST-Firmware" or the "UIR-Firmware" command button to
2.
select the path and file name of the desired firmware.
Firmware files have the file name extension ".hex".
The selected firmware file will be displayed in the corresponding in­
put fields.
A separate selection of the UIR firmware („UIR firmware" command
button) is not necessary for type PSI 6xCx.xxx timers.
Select the timer(s) for which the firmware update is to be carried out
3.
by ticking the proper check boxes at the left margin of the lines.
To select/deselect all of the timers, use the check box at the left mar­
gin of the table's header line.
Bosch Rexroth AG
401 / 460
Service and repair

Advertisement

Chapters

Table of Contents
loading

Table of Contents