Assembly
Feedback to weld timer
Different type-specific options are available to signal gun closed or pro­
grammed force reached to the timer.
The required option can normally be selected through the "Operating
mode" parameter in the "Programming / Electrode" BOS window.
The existence of the „Operating mode" parameter is also type-speci­
fic.
GND for terminals 1 and 3
analog pressure input (0...10V)
digital pressure input (+24 V
analog force input (1 V = 1 kN)

Fig. 77: Possibly available feedback signal inputs for pressure/force

Information on the inputs available in your unit and how the WT re­
acts to these signals is provided in the type-specific manual.
PSI 6xxx |
Timer
X2
1
2
3
)
4
DC
5
Shield
X9
1
2
3
4
GND
5
Shield
6
1070080028 / 08
D
D