Siemens SINAMICS S120 Manual page 39

Cabinet modules liquid cooled
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Compliance with standards
Standards
CE marking
Ambient conditions
Ambient temperature
Relative humidity
(condensation not permissi-
ble)
corresponds to class
Environmental class / harm-
ful chemical substances
Organic/biological influ-
ences
Mechanically active sub-
stances
Installation altitude
Deviations from the specified class are shown in
2)
Mechanical strength
Vibrational load
- Displacement
- Acceleration
- Corresponds to class
Shock load
- Acceleration
- Corresponds to class
Deviations from the specified class are shown in
2)
NOTICE
Damage to the device through incorrect storage and transport of liquid-cooled devices
The storage and transport of liquid-cooled devices that have not been completely emptied
can result in damage to the device through freezing.
• Always empty the liquid-cooled devices completely before storage or transport.
Cabinet Modules liquid cooled
Equipment Manual, 04/2020, A5E37067587A
EN 50274, EN 60146-1, EN 60204-1, EN 60529, EN 61800-2, EN 61800-3, EN 61800-5-1
- EMC Directive No. 2014/30/EU
- Low-Voltage Directive No. 2014/35/EU
- Machinery Directive No. 2006/42/EC for functional safety
During storage
2)
-25° C to +55° C
5 % ... 95 %
1K4 acc. to EN 60721-3-
1:1997
1C2 acc. to EN 60721-3-
1:1997
1B1 acc. to EN 60721-3-
1:1997
1S1 acc. to EN 60721-3-
1:1997
up to 2000 m above sea level - no derating,
> 2000 m - see characteristics/derating data
italics
During storage
2)
5 Hz
1.5 mm at
... 9 Hz
5 m/s² at > 9 ... 200 Hz
1M2 acc. to EN 60721-3-1:
1997
40 m/s
for 22 ms
2
1M2 acc. to EN 60721-3-
1:1997
italics
During transport
2)
-25° C to +70° C
-40 °C
from
for 24 hours
5 % ... 95 % at 40 °C
2K3 acc. to EN 60721-3-
2:1997
2C2 acc.to EN 60721-3-
2:1997
2B1 acc.to EN 60721-3-
2:1997
2S1 acc.to EN 60721-3-
2:1997
.
During transport
2)
5 Hz
3.1 mm at
... 9 Hz
10 m/s² at > 9 ... 200 Hz
2M2 acc. to EN 60721-3-
2:1997
100 m/s
for 11 ms
2
2M2 acc. to EN 60721-3-2:
1997
.
System overview
2.10 System data
In operation
2)
0 °C
... +45 °C
to +50 °C see derating data
95 %
5 % ...
3K3 acc.to EN 60721-3-
3:2002
3C2 acc.to EN 60721-3-
3:2002
3B1 acc. to EN 60721-3-
3:2002
3S1 acc.to EN 60721-3-
3:2002
In operation
2)
0.075 mm at 10 ... 58 Hz
9.8 m/s² at >58 ... 200 Hz
-
100 m/s
for 11 ms
2
3M4 acc. to EN 60721-3-
3:2002
37

Advertisement

Table of Contents
loading

Table of Contents