Bosch BSA 43 Series Original Instructions Manual page 52

Test lane with pc for passenger vehicles
Hide thumbs Also See for BSA 43 Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 39
en
52 | BSA 43xx | Manual mode (normal operation)
Step
5. Braking force measurement:
Slowly and steadily depress brake
pedal until maximum braking force
(slip) is attained.
Release brake pedal again.
i
Shut-off criteria:
$
Wheel lock-up (slip monitoring).
$
Motorcycle drift (touch roller no
longer pressed).
$
Maximum braking force (slip) not
attained on braking and braking
action remains at rolling resistance
level for more than six seconds.
6. End of measurement for tester
without motor brake.
Start of measurement
Drive motorcycle off set of rollers.
|
1 691 606 210
2015-07-29
Remote control
Result / Display
 The current values are displayed on the screen:
$
Braking force (F)
$
Pedal force (PD)
$
Braking factor (Z)
 Peak value display (approx. 5 seconds).
"
The measured values can now be stored.
"
Braking force measurement over.
+
+
Robert Bosch GmbH

Advertisement

Table of Contents
loading

Table of Contents