Upgrade Guide
USG9520's Device status:
Slot #
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
1
6
8
9
10
11
12
13
14
15
16
17
18
19
When Unregistered is displayed in the Register column, it indicates that the board in the slot
fails to be registered. When Abnormal is displayed in the Status column, it indicates that the
board in the slot is running abnormally.
When the board in a certain slot cannot be registered or runs abnormally, record the board
status and contact technical support personnel to check whether the device can be upgraded or
the board needs to be replaced. After the upgrade, check the status of the board. If the board
cannot run normally still, contact technical support personnel.
Checking Session Statistics
In any view, run the display firewall session statistics command to check session statistics.
You need to record the session statistics before and after upgrade for comparison. This will
help you check whether the services of the device are normal after upgrade.
<USG9500> display firewall session statistics
Session Statistics:
Slot
Slot
Slot
Slot
Total 0 session(s) on all slots.
Session Creation Rate(num/s):
Slot
Slot
Slot
Slot
Total session(s) creation rate on all slots is 0.
Checking Traffic Statistics
In any view, run the display interface interface-type interface-number command to check the
traffic statistics on a service interface. You need to record the traffic statistics before and after
upgrade for comparison. This will help you check whether the services of the device are
normal after upgrade.
The following is sample output from this command on GigabitEthernet 1/0/2:
<USG9500> display interface GigabitEthernet 1/0/2
GigabitEthernet1/0/2 current state : UP
Line protocol current state : UP
Description: test
Issue 01 (2018-01-16)
type
online
LPU
Present
SPU
Present
LPU
Present
MPU
Present
MPU
Present
SFU
Present
SFU
Present
SFU
Present
SFU
Present
CLK
Present
CLK
Present
PWR
Present
PWR
Present
FAN
Present
NOTE
If NA is displayed in the Register field, the board is a master MPU.
6 cpu 0:
0
6 cpu 1:
0
6 cpu 2:
0
6 cpu 3:
0
6 cpu 0:
0
6 cpu 1:
0
6 cpu 2:
0
6 cpu 3:
0
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
register
status
Registered
Normal
Registered
Normal
Registered
Normal
NA
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
Registered
Normal
2 USG9500
primary
NA
NA
NA
Master
Slave
NA
NA
NA
NA
Master
Slave
NA
NA
NA