Configuring Safety Integrated Plus (F-Plc) - Siemens SINUMERIK 840D sl Configuration Manual

Sinumerik step 7 toolbox v15.1
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Safety configuration

10.8 Configuring Safety Integrated plus (F-PLC)

● F-blocks
● Access protection
● Settings
F-libraries
You can not only store F-blocks in global libraries and project libraries as master copies, but
also use them as already tested and approved safety functions.
However, you must observe additional conditions, which are described in the following help
functions:
Help on SIMATIC Safety, Section "Acceptance of the system"
TIA Portal online help, Section "Libraries"
Reserved block numbers for SINUMERIK Safety Integrated plus (F-PLC)
An F-runtime group is created when you activate Safety Integrated plus (F-PLC) mode. An
associated F-FB, F-FC and F-DB is created in the reserved number range for F-runtime groups:
Reserved number range for F-runtime groups
● F-FB 1010..1019
● F-FC 1010..1019
● F-DB 1010..1019
Further reserved number range for F-runtime groups
● F-FB: 3999..7999
● F-FC: 3999..7999
● F-DB: 8000..16000
See also: Assignment overview (Page 66)Creating a second F-runtime group for Safety
Integrated plus (F-PLC) (Page 204)
Further information
Detailed information on the Safety Administration Editor can be found in the Programming and
Operating Manual SIMATIC Safety – Configuring and Programming, or in the section with the
same name in the TIA Portal online help.
10.8.2
Configuring Safety Integrated plus (F-PLC)
The following basic procedure only roughly lists the project planning steps that are performed
in TIA Portal and specific to SINUMERIK. Commissioning is described in detail in the following
documentation:
● SINUMERIK Safety Integrated plus Commissioning Manual
The SINUMERIK Safety Integrated plus documentation only serves to clarify the special
features in contrast to a S7-300 CPU and are only meant to be an introduction to configuring
and programming STEP 7 Safety Advanced with SINUMERIK.
202
SINUMERIK STEP 7 Toolbox V15.1
Configuration Manual, 12/2018, A5E46279635B AA

Hide quick links: