Function And Parameterization Of The V/F Control (V/F Reg Param); V/F Regulation Control (V/F Control) - GE AV-300i User Manual

Hide thumbs Also See for AV-300i:
Table of Contents

Advertisement

1.4.3 Function and parameterization of the V/f Control (V/f Reg Param)

1.4.3.1 V/f Regulation Control (V/f Control)

When the motor is loaded, the mechanical speed changes according to the applied load.
In order to reduce the speed error, it is possible to compensate for the motor slip.
The function parameterization allows:
-
to increase the output voltage with low frequencies (voltage Boost)
-
to compensate the speed change due to a load increase
-
to parameterize a filter on the compensation
-
to damp the DC link oscillations
The V/f mode has no current regulator.
A pseudo-regulator changes the output frequency in order to prevent the current from overcoming the set current limit.
Description:
REGULATION PARAM
V/f reg param
V/f control
Voltage boost
Slip comp
Slip comp filter
Antioscill gain
V/f ILim P gain
V/f ILim I gain
REGULATION PARAM
AV-300i Version 2 User's Guide
Dead time compensation
v
+
Output voltage
+
SAVE
PARAMETERS
—————— Function Description ——————
Dead time slope
Dead time limit
i
Voltage cmd to pwr
Ch.1
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents