1-7. Rack Mounting

The DSM-T1 can be mounted in a 19-inch standard rack.
m
. If the DSM-T1 or the peripheral equipment are mounted
in a 19-inch standard rack, it is recommended to install a
ventilation fan to prevent a temperature rise in the rack.
Make sure that all the units in the rack should be
operated within the temperature range of 0 dC to 40 dC.
. Connect the enough long cables on the rear panel,
considering that the DSM-T1 is pulled out.
. To prevent falling the rack, fix it on the horizontal firm
floor with bolts.
Required parts
. Rack Mount Kit, RMM-30 (Option)
or
RACK-MOUNT SLIDES, Model 305A
Manufactured by Accuride
Slide length 558.8 mm (22 inch)
c
Be sure to use the specified rack mount rail.
If a rack mount rail other than the specified one is used, the
DSM-T1 may be dropped by insufficient strength of the
rack mount rail. This may cause a injury.
The following parts are supplied with the DSM-T1.
. Rack angle (1U) Assembly : 2 pcs.
. Rail bracket
. Screw (K 4x14)
. Screw (B 4x14)
. Screw (B 4x8)
. Screw (B 5x12)
. Screw (RK 5x14)
. Plate nut (small)
. Plate nut (large)
. Spring washer ø5
. Washer ø5
. Washer ø4
. Ornamental washer
DSM-T1
: 4 pcs.
: 4 pcs.
: 4 pcs.
: 8 pcs.
: 8 pcs.
: 4 pcs.
: 4 pcs.
: 4 pcs.
: 8 pcs.
: 8 pcs.
: 4 pcs.
: 4 pcs.
Procedures
1. Turn the power of the DSM-T1 off.
2. Remove the four feet from the bottom of the DSM-T1.
B 3x10
Feet
B 3x10
Feet
3. Attach the inner rails to the DSM-T1 using the screws
(K 4x14).
K 4x14
4. Attach the rack angle (1U) assemblies to the DSM-T1
using the screws (B 4x14) and washers (ø4).
B 4x14
Washers ø4
Rack angle
(1U) assemblies
1-7. Rack Mounting
Inner rails
K 4x14
Washers ø4
B 4x14
1-5 (E)