Toshiba Strata DK 16 Installation And Maintenance Manual page 276

Toshiba digital key telephone systems installation and maintenance manual
Hide thumbs Also See for Strata DK 16:
Table of Contents

Advertisement

REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
STEP
1
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2
Enter Program Number
Refer to the record sheet and enter the desired program number.
Example: Program 10-1, enter 1 0, press CR.
3
Enter Program Code or Digit(s) Per Record Sheet
1 or other digit required.
NOTE: Most programs do not require a second digit.
4
Enter Button/LED Number
Enter the desired button/LED number.
Example: Button/LED 01, enter 0 1.
5
To Change Button/LED Status
Refer to the System Record Sheet and change the button/LED
status, if required (Y or N).
Example: Enter Y.
6
To Advance to Next Button/LED
Press SPACE. Repeat step 5 if necessary.
7
To Review Button/LED Status Change
Enter CR.
Re-enter Steps 3 and 4.
NOTE: This step is optional and not required to save data.
8
To Exit Program/Store Data
To store data, press CR.
A)
B)
To exit this program, press # #, then press CR.
C)
Continue returning to step 2 until all Type 1 programs
are completed.
9
To Exit the Program Mode
Press # # CR.
To Enter Another Mode
10
Press
D U M P CR (data dump)
T E S T CR
M E S G CR
R E P T CR
NOTE:
Y = button/LED "ON", N = button/LED "OFF"
TABLE RM-Q
TYPE 1 PROGRAM PROCEDURE EXAMPLE
(PROGRAMS: 10-1, 10-2, 10-3, 15, 16, 42-0, 77-1, 77-2)
ACTION
(test)
(LCD messages)
(speed dial)
-26-
DISPLAY/PRINTOUT
>MODE PROG
P
P 10
P10
P10 1
P10 1 01 N
(see note)
P10 1 01 N Y
P10 1 01 Y
02 N
P10 1 01 Y-
Button LED "ON"
Button LED Number
Program Code
Program Number
P10
P10 ##
P
> MODE
D
T
(no prompt)
R

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk8