Commissioning; Configuration; Reconfiguration - Siemens SINUMERIK 840D sl Function Manual

Extended functions
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

15.3

Commissioning

15.3.1

Configuration

The configuration of the local static and dynamic NC memory is set and influenced by the
following machine data:
● Machine data that configure the memory:
– $MN_MM_... (NC-specific, memory-configuring machine data)
– $MC_MM_... (channel-specific memory-configuring machine data)
– $MA_MM_... (axis-specific memory-configuring machine data)
● Number of parameterized channels:
– MD10010 $MN_ASSIGN_CHAN_TO_MODE_GROUP (channel valid in mode group)
15.3.2

Reconfiguration

The first time the controller starts up, the sizes of the memory areas of the local NC memory
are set based on the default settings of the memory-configuring machine data. Generally, these
settings are sufficient for the operation of the control. If the memory areas of the local NC
memory are adapted because of special user-specific requirements, this results in
reconfiguration of the local NC memory. If the active and/or passive file system of the static
NC memory is affected, Alarm 4400 is displayed. The user should then back up the relevant
data by creating a commissioning archive on an external storage medium.
Alarm 4400 is displayed in the following cases:
● Memory-configuring machine data of the passive file system was changed
● Memory-configuring machine data of the active file system was changed and the function
"Automatic Memory Reconfiguration" (AMR) is not active
● Memory-configuring machine data of the active file system was changed, the AMR function
is active, but the data of the active file system cannot be buffered locally
NOTICE
Loss of data due to reconfiguration
A reconfiguration of the local static NC memory can result in the loss of the user data on the
active and/or passive file system. We therefore urgently recommend the back up of all relevant
data by creating a commissioning archive if Alarm 4400 is displayed, before activating the
changed memory configuration by an NC reset.
Extended Functions
Function Manual, 10/2015, 6FC5397-1BP40-5BA3
S7: Memory configuration
15.3 Commissioning
801

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents