Registration adjustment range is from +2pixels to -
2 pixels with an increment of adjustment of +/-1 pixel.
Test Pattern
Tap the appropriate Plus
align the Red, Green and Blue images as observed on
the auditorium screen.
Note: Insure that Lens Focus is optimized prior to
starting the registration process. In some cases it may
be beneficial to use a white sheet of paper placed flat
against the screen so you can see the black/white
transition to verify lens focus (use crosshatch pattern)
and also to make it easier to see registration errors.
When the image is properly registered, click Next. The
Registration Adjustment screen closes and you are
returned to the Menu,

Filter Timer Reset

Tracking the number of hours of operation on filtering for
the projector's Optical area, with separate tracking for the
Power Supply Converter filter is available. This feature
allows you to monitor the number of hours on the filters
and replace them before they effect either airflow or the
quality of cooling air in the projector
61
Theater Setup
Finish
or Minus
button to
Access to the Filter Timer reset feature uses the pre-
defined Theater Setup login "trsetup" thus insuring that the
Resets are carried out by only qualified personnel.
Reset
Tap Reset for the associated filter and then tap Close
to return to the Menu.