Installation
Please note:
• Set the delivery volume
(see page 15 and 18),
before removing the
plug and screwing the
lubrication unit in the
support bracket.
• The oil container may only
be bolted 1x.
• Oil may leak from the
oil container during the
following operations.
1.
Label the oil container
with the assembly and
the expiration date.
2.
Remove the oil container
plug.
3.
Screw the lubrication
unit by hand into the
support bracket (E).
4.
Close the holder (D).
5.
Remove the protective
cap.
6.
Connect the connection
cable to the lubrication
unit.
Please note:
• After connecting the power
cable and with supply
voltage present, the LED
indicators fl ash green (GN)
in 5 s intervals.
• A fl ashing arrow icon
appears in the display.
• The lubricating unit is ready
for operation with the
parameters previously set.
Bosch Rexroth AG, MIT: LU 2, 3 842 358 814/2017-01
GN
D
4
E
Fig. 12:
Install drive with oil container LC 2 in support bracket
Please note:
Only in pulse
mode:
After re-establishing the supply voltage
carried out. During the delivery the drive and the LED indicators fl ash at 1 s intervals.
2
6
5
GN
4
3
1
1...
2
358 814-22
a delivery process is

Hide quick links: