6.1.1

Setting the delivery volume in the TIME operating mode

The mode of operation, the oil container used LC 2 (
period is entered via the display using the SET button.
The delivery period must be entered in relation to the required delivery volume,
interval period and the oil tank used LC 2 (
• The input is executed with the power supply disconnected. The power supply for
the electronics comes from an integrated backup battery.
• The oil container LC 2 must be installed on the drive prior to the setting
(see page 31).
In the as delivered condition the display is on the left.
358 814-27
1.
Press and hold the SET button (> 5 s), until the modes TIME and PULSE fl ash
in the display.
2.
Press 1x the SET button.
358 814-28
The display switches to the TIME mode (TIME fl ashes).
358 814-29
After about 3 seconds, the display switches to the selection of the oil container.
3.
Press SET button 1x
Press SET button 2x
358 814-30
Press SET button 3x
The selected oil container fl ashes in the display (here LC250).
358 814-31
After about 3 seconds, the display switches to the entry of the metered lubricant
delivery period.
358 814-32
4.
To enter the delivery period press the SET button repeatedly.
Months
1
1 2
can be scrolled through.
...
The delivery period entered fl ashes in the display.
Approximately 3 seconds after the entry (inactive SET button) the setting mode
358 814-33
for the delivery period is terminated.
The operating mode, the entered delivery period, the entered oil container LC 2
(
LC250) and the metered volume to be delivered per 100 hours are shown on
the display.
358 814-34
LC250) and the delivery
LC250) (see Table 5 on page 14).
LC60
LC120
LC250 (= LC 2)
3 842 358 814/2017-01, MIT: LU 2, Bosch Rexroth AG
Function
15/54