4.
5.
Installing a Power Module
To install a power module, do the following:
1.
2.
3.
4.
5.
6.
RUGGEDCOM RX1510
Installation Manual, 12/2019, C79000-G8976-1055-16
Disconnect the power supply wiring from the terminal block. Alternatively, for
convenience, remove the terminal block with the wiring still connected and set
it aside to be connected later to the new module.
Install a new or blank module to prevent the ingress of dust and dirt.
If equipped, remove the existing module.
If applicable, connect the supplied terminal block to the module or connect the
terminal block from the previous module.
Confirm or connect the wiring from the power supply to the module. For more
information, refer to
Insert the module into the empty slot.
Chassis
1
Screws
2
Power Module
3
Figure 4.6
Installing a Power Module
Hand-tighten the screws to secure the power module to the chassis.
Turn on power to the device and confirm the module is receiving and supplying
power. This is indicated by the LEDs on the module.
LED
O
I
4.3 Installing/Removing Power Modules
"Connecting Power (Page
State
Green
The module is supplying power
Green
The module is receiving power