Siemens SINAMICS S120 Manual page 350

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Motor Modules Booksize
6.1 Safety instructions for Motor Modules Booksize
NOTICE
Damage through use of incorrect DRIVE-CLiQ cables
Damage or malfunctions can occur on the devices or system when DRIVE-CLiQ cables are
used that are either incorrect or have not been approved for this purpose.
• Only use suitable DRIVE-CLiQ cables that have been approved by Siemens for the
Note
Malfunctions due to polluted DRIVE-CLiQ interfaces
Malfunctions can occur in the system through the use of polluted DRIVE-CLiQ interfaces.
• Cover unused DRIVE-CLiQ interfaces with the supplied blanking covers.
Special features for Motor Modules with external air cooling
Note
Insufficient cooling power when the external heat sinks are polluted
For components with external air cooling, the fan and the heat sinks can accumulate a lot of
pollution. If the cooling air requirement is not provided by the filter fan, the components
cannot output their specified power. This can cause the temperature monitoring function in
the components to respond.
• Check the fans and heat sinks for pollution at regular intervals and clean them when
necessary.
Note
Checking the seal
• After installation, check the seal on the rear of the device to ensure that it is tight.
• If required, use additional sealing.
Note
Using an installation frame
• Only use an installation frame when the cabinet has an unpainted metal surface.
Notes for UL applications
Note
The SINAMICS S120 Motor Modules Booksize provide short-circuit protection at the motor
output terminals.
350
particular application.
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8