Configuring/address space
4.3 Manual operation (without technology object)
4.3.3.2
Parameters (incremental or pulse encoder)
Parameters of the TM PosInput 2 with incremental or pulse encoder
The following parameter settings are possible:
Table 4- 12
Settable parameters and their default setting (incremental or pulse encoder)
Parameter
Operating mode
3
Reaction to CPU STOP
1
Substitute value for DQ0
Substitute value for DQ1
Enable diagnostic interrupt
on wire break
2
Enable additional diagnostic
interrupts
Hardware interrupt: New
Capture value available
1
Hardware interrupt: Syn-
chronization of the counter
by an external signal
1
Hardware interrupt: Gate
start
1
Hardware interrupt: Gate
stop
1
Hardware interrupt: Over-
flow (high counting limit
violated)
1
Hardware inter-
rupt:Underflow (low count-
ing limit violated)
1
Hardware interrupt: Direc-
tion reversal
1
60
Value range
Counting
•
Measuring
•
Output substitute value
•
Keep last value
•
Continue operation
•
1
0
•
1
•
1
0
•
1
•
Deactivated
•
Activated
•
Deactivated
•
Activated
•
Deactivated
•
Activated
•
Deactivated
•
Activated
•
Deactivated
•
Activated
•
Deactivated
•
Activated
•
Deactivated
•
Activated
•
Deactivated
•
Activated
•
Deactivated
•
Activated
•
Default setting
Parameter
reassign-
ment in RUN
Counting
No
Output substitute
Yes
value
0
Yes
0
Yes
Deactivated
Yes
Deactivated
Yes
Deactivated
Yes
Deactivated
Yes
Deactivated
Yes
Deactivated
Yes
Deactivated
Yes
Deactivated
Yes
Deactivated
Yes
Technology module TM PosInput 2 (6ES7551-1AB00-0AB0)
Manual, 06/2018, A5E03982218-AB
Scope
HSP for STEP 7
(TIA Portal);
GSD file
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel