56 Actual signals and parameters
All parameters
No.
Name/
Value
6004
PV CELL MIN
VOLT
109...800 V
6005
PV CELL MAX
VOLT
109...800 V
6006
PUMP
MINIMUM SPD
0...3000 rpm
6007
PUMP
MAXIMUM SPD
0...3000 rpm
6008
BOOST VOLT
109...600 V
6009
BOOST
FACTOR
0.75...1.25
6015
DRY RUN SEL
DI
DI1
DI2
Description
Defines the minimum DC voltage below which the
inverter cannot operate.
Note: The inverter stops operating below this voltage.
DC voltage.
Note: Range is different for 1-phase and 3-phase
inverters.
Defines the maximum DC voltage. At any value above
this voltage, the inverter trips due to
fault.
DC voltage.
Note: Range is different for 1-phase and 3-phase
inverters.
Defines the minimum motor speed. At any value below
this speed, the inverter stops functioning and auto
restarts after the time defined in
TIME. This setting avoids unnecessary operation of
pump at low speed.
Speed
Defines the maximum motor speed.
Speed
Defines the DC voltage above which 6009 BOOST
FACTOR is effective. Below this value, motor speed
follows the V/F factor.
DC voltage.
Note: Range is different for 1-phase and 3-phase
inverters.
Defines the factor at which the inverter functions the
best. This parameter is effective when DC voltage is
above the value in 6008 BOOST VOLT.
Boost factor
Selects the input for dry run protection.
Digital input DI1. Defines the digital input DI1 as the
control for dry run protection.
See selection DI1.
PV MAX VOLT
6019 FAULT RESET
Def/ FbEq
1 = 1 V
400 V unit:
225
200 V unit:
129
1 = 1 V
400 V unit:
640
200 V unit:
368
1 = 1 rpm
0
1 = 1 rpm
3000
1 = 1 V
400 V unit:
450
200 V unit:
259
100 = 1
1.00
WITH_
P60.16
1
2