Sp-## Special Functions - GE AF-650 GP Programming Manual

General purpose drive
Hide thumbs Also See for AF-650 GP:
Table of Contents

Advertisement

Parameter Descriptions

3.9 SP-## Special Functions

Parameter group related to special functions with regards
to Line Voltage, Reset Functions, Current Limit, Energy
Savings, Derating, and Accel/Decel Ramp Types.
SP-00 Fault Level
Option:
Function:
[0]
Off
Use this parameter to customize Fault levels. Use
*
[0] Off with caution as it will ignore all Warnings
& Alarms for the chosen source.
[1]
Warning
[2]
Trip
[3]
Trip Lock
Failure
10 V low
24 V low
1.8 V supply low
Voltage limit
Earth fault during ramping
Earth fault 2 during cont. operation
Torque Limit
Over Current
Short Circuit
Heatsink temperature
Heatsink sensor
Control card temperature
Power card temperature
1)
Heatsink temperature
1)
Heatsink sensor
1)
Power card temperature
Table 3.16 Table for Selection of Choice of Action when Selected Alarm Appears
D = Default setting
x = possible selection
1) Only drives 125 HP and above. All others is just a warning.
AF-650 GP Programming Guide
Alarm
Off
1
X
47
X
48
X
64
X
14
45
12
X
13
16
29
39
65
69
244
245
247
DET-618C
Warning
Trip
D
D
D
D
D
X
X
X
X
X
1)
X
X
X
3
3
Trip Lock
D
D
X
X
D
D
D
D
D
D
D
D
77

Hide quick links:

Advertisement

Table of Contents
loading